Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Fenestration Performance: 7

glass only center to skylight glass only center

ASHRAE Chapter 15 fenestration U-factors (W/m²·K) for windows, skylights, curtain walls, and doors by glazing configuration and frame type. Covers single through quadruple glazing with air, argon, and krypton fill, low-e coatings at various emissivities, and all major frame materials. Source: ASHRAE Handbook Fundamentals 2021 Tables 4 and 6.

Mechanical Engineeringglazing id: 710 rowsPage 2 of 3
glazing idframe typegap fillgap mm (mm)glazing categoryglazing typenum panes (dimensionless)u factor Wm2K (W/(m2·K))
7glass only centerargon13Double Glazing13 mm argon space22.56
7glass only edgeargon13Double Glazing13 mm argon space23.24
7operable alum no breakargon13Double Glazing13 mm argon space24.16
7operable alum thermal breakargon13Double Glazing13 mm argon space23.18
7operable insul fiberglass vinylargon13Double Glazing13 mm argon space22.46
7operable reinf vinyl alum cladargon13Double Glazing13 mm argon space22.84
7operable wood vinylargon13Double Glazing13 mm argon space22.74
7skylight alum no breakargon13Double Glazing13 mm argon space25.96
7skylight alum thermal breakargon13Double Glazing13 mm argon space25.19
7skylight glass only centerargon13Double Glazing13 mm argon space23.01