Fenestration Performance: 6
glass only center to skylight glass only center
ASHRAE Chapter 15 fenestration U-factors (W/m²·K) for windows, skylights, curtain walls, and doors by glazing configuration and frame type. Covers single through quadruple glazing with air, argon, and krypton fill, low-e coatings at various emissivities, and all major frame materials. Source: ASHRAE Handbook Fundamentals 2021 Tables 4 and 6.
| glazing id | frame type | gap fill | gap mm (mm) | glazing category | glazing type | num panes (dimensionless) | u factor Wm2K (W/(m2·K)) |
|---|---|---|---|---|---|---|---|
| 6 | glass only center | argon | 6 | Double Glazing | 6 mm argon space | 2 | 2.9 |
| 6 | glass only edge | argon | 6 | Double Glazing | 6 mm argon space | 2 | 3.48 |
| 6 | operable alum no break | argon | 6 | Double Glazing | 6 mm argon space | 2 | 4.43 |
| 6 | operable alum thermal break | argon | 6 | Double Glazing | 6 mm argon space | 2 | 3.44 |
| 6 | operable insul fiberglass vinyl | argon | 6 | Double Glazing | 6 mm argon space | 2 | 2.69 |
| 6 | operable reinf vinyl alum clad | argon | 6 | Double Glazing | 6 mm argon space | 2 | 3.08 |
| 6 | operable wood vinyl | argon | 6 | Double Glazing | 6 mm argon space | 2 | 2.98 |
| 6 | skylight alum no break | argon | 6 | Double Glazing | 6 mm argon space | 2 | 5.96 |
| 6 | skylight alum thermal break | argon | 6 | Double Glazing | 6 mm argon space | 2 | 5.19 |
| 6 | skylight glass only center | argon | 6 | Double Glazing | 6 mm argon space | 2 | 3.01 |