Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Fenestration Performance: 6

glass only center to skylight glass only center

ASHRAE Chapter 15 fenestration U-factors (W/m²·K) for windows, skylights, curtain walls, and doors by glazing configuration and frame type. Covers single through quadruple glazing with air, argon, and krypton fill, low-e coatings at various emissivities, and all major frame materials. Source: ASHRAE Handbook Fundamentals 2021 Tables 4 and 6.

Mechanical Engineeringglazing id: 610 rowsPage 2 of 3
glazing idframe typegap fillgap mm (mm)glazing categoryglazing typenum panes (dimensionless)u factor Wm2K (W/(m2·K))
6glass only centerargon6Double Glazing6 mm argon space22.9
6glass only edgeargon6Double Glazing6 mm argon space23.48
6operable alum no breakargon6Double Glazing6 mm argon space24.43
6operable alum thermal breakargon6Double Glazing6 mm argon space23.44
6operable insul fiberglass vinylargon6Double Glazing6 mm argon space22.69
6operable reinf vinyl alum cladargon6Double Glazing6 mm argon space23.08
6operable wood vinylargon6Double Glazing6 mm argon space22.98
6skylight alum no breakargon6Double Glazing6 mm argon space25.96
6skylight alum thermal breakargon6Double Glazing6 mm argon space25.19
6skylight glass only centerargon6Double Glazing6 mm argon space23.01