Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Fenestration Performance: 5

glass only center to skylight glass only center

ASHRAE Chapter 15 fenestration U-factors (W/m²·K) for windows, skylights, curtain walls, and doors by glazing configuration and frame type. Covers single through quadruple glazing with air, argon, and krypton fill, low-e coatings at various emissivities, and all major frame materials. Source: ASHRAE Handbook Fundamentals 2021 Tables 4 and 6.

Mechanical Engineeringglazing id: 510 rowsPage 2 of 3
glazing idframe typegap fillgap mm (mm)glazing categoryglazing typenum panes (dimensionless)u factor Wm2K (W/(m2·K))
5glass only centerair13Double Glazing13 mm airspace22.73
5glass only edgeair13Double Glazing13 mm airspace23.36
5operable alum no breakair13Double Glazing13 mm airspace24.3
5operable alum thermal breakair13Double Glazing13 mm airspace23.31
5operable insul fiberglass vinylair13Double Glazing13 mm airspace22.58
5operable reinf vinyl alum cladair13Double Glazing13 mm airspace22.96
5operable wood vinylair13Double Glazing13 mm airspace22.86
5skylight alum no breakair13Double Glazing13 mm airspace26.17
5skylight alum thermal breakair13Double Glazing13 mm airspace25.41
5skylight glass only centerair13Double Glazing13 mm airspace23.24

What else is in Engineering Database

Related data