Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Fenestration Performance: 19

operable alum no break to skylight wood vinyl

ASHRAE Chapter 15 fenestration U-factors (W/m²·K) for windows, skylights, curtain walls, and doors by glazing configuration and frame type. Covers single through quadruple glazing with air, argon, and krypton fill, low-e coatings at various emissivities, and all major frame materials. Source: ASHRAE Handbook Fundamentals 2021 Tables 4 and 6.

Mechanical Engineeringglazing id: 1910 rowsPage 2 of 3
glazing idframe typegap fillgap mm (mm)glazing categoryglazing typelow e emissivity (dimensionless)low e surfacenum panes (dimensionless)u factor Wm2K (W/(m2·K))
19operable alum no breakargon13Double Glazing Low-E13 mm argon e=0.200.22or323.47
19operable alum thermal breakargon13Double Glazing Low-E13 mm argon e=0.200.22or322.53
19operable insul fiberglass vinylargon13Double Glazing Low-E13 mm argon e=0.200.22or321.88
19operable reinf vinyl alum cladargon13Double Glazing Low-E13 mm argon e=0.200.22or322.24
19operable wood vinylargon13Double Glazing Low-E13 mm argon e=0.200.22or322.14
19skylight alum no breakargon13Double Glazing Low-E13 mm argon e=0.200.22or325.24
19skylight alum thermal breakargon13Double Glazing Low-E13 mm argon e=0.200.22or324.47
19skylight glass only centerargon13Double Glazing Low-E13 mm argon e=0.200.22or322.27
19skylight reinf vinyl alum cladargon13Double Glazing Low-E13 mm argon e=0.200.22or324.24
19skylight wood vinylargon13Double Glazing Low-E13 mm argon e=0.200.22or323.89

What else is in Engineering Database