Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Fenestration Performance: 1

glass only center to skylight reinf vinyl alum clad

ASHRAE Chapter 15 fenestration U-factors (W/m²·K) for windows, skylights, curtain walls, and doors by glazing configuration and frame type. Covers single through quadruple glazing with air, argon, and krypton fill, low-e coatings at various emissivities, and all major frame materials. Source: ASHRAE Handbook Fundamentals 2021 Tables 4 and 6.

Mechanical Engineeringglazing id: 110 rowsPage 2 of 3
glazing idframe typegap fillglazing categoryglazing typenum panes (dimensionless)u factor Wm2K (W/(m2·K))
1glass only centerairSingle Glazing3.2 mm glass15.91
1operable alum no breakairSingle Glazing3.2 mm glass17.01
1operable alum thermal breakairSingle Glazing3.2 mm glass16.08
1operable insul fiberglass vinylairSingle Glazing3.2 mm glass14.83
1operable reinf vinyl alum cladairSingle Glazing3.2 mm glass15.27
1operable wood vinylairSingle Glazing3.2 mm glass15.2
1skylight alum no breakairSingle Glazing3.2 mm glass110.03
1skylight alum thermal breakairSingle Glazing3.2 mm glass19.68
1skylight glass only centerairSingle Glazing3.2 mm glass16.76
1skylight reinf vinyl alum cladairSingle Glazing3.2 mm glass19.16

What else is in Engineering Database