Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Effectiveness Ntu: Shell-and-tube 1-pass

0.75 1.5 to 1.00 1.5

Heat exchanger effectiveness (ε) vs. number of transfer units (NTU) and capacity ratio (Cr = Cmin/Cmax) for seven flow configurations: parallel-flow, counterflow, shell-and-tube 1-pass, shell-and-tube 2-pass, crossflow both unmixed, crossflow Cmin mixed, crossflow Cmax mixed. Data digitized from Incropera Figures 11.10-11.15.

Mechanical Engineeringhx configuration: Shell-and-tube 1-pass10 rowsPage 4 of 5
hx configurationskcapacity ratio (dimensionless)effectiveness (dimensionless)ntu (dimensionless)
Shell-and-tube 1-pass0.75 1.50.750.581.5
Shell-and-tube 1-pass0.75 2.00.750.632
Shell-and-tube 1-pass0.75 2.50.750.662.5
Shell-and-tube 1-pass0.75 3.00.750.673
Shell-and-tube 1-pass0.75 4.00.750.694
Shell-and-tube 1-pass0.75 5.00.750.695
Shell-and-tube 1-pass1.00 0.0100
Shell-and-tube 1-pass1.00 0.510.30.5
Shell-and-tube 1-pass1.00 1.010.461
Shell-and-tube 1-pass1.00 1.510.521.5