Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Effectiveness Ntu: Crossflow both unmixed

1.00 2.0 to 1.00 5.0

Heat exchanger effectiveness (ε) vs. number of transfer units (NTU) and capacity ratio (Cr = Cmin/Cmax) for seven flow configurations: parallel-flow, counterflow, shell-and-tube 1-pass, shell-and-tube 2-pass, crossflow both unmixed, crossflow Cmin mixed, crossflow Cmax mixed. Data digitized from Incropera Figures 11.10-11.15.

Mechanical Engineeringhx configuration: Crossflow both unmixed5 rowsPage 5 of 5
hx configurationskcapacity ratio (dimensionless)effectiveness (dimensionless)ntu (dimensionless)
Crossflow both unmixed1.00 2.010.642
Crossflow both unmixed1.00 2.510.72.5
Crossflow both unmixed1.00 3.010.753
Crossflow both unmixed1.00 4.010.824
Crossflow both unmixed1.00 5.010.865

What else is in Engineering Database

Related data