Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Effectiveness Ntu: Crossflow both unmixed

0.25 0.5 to 0.50 0.5

Heat exchanger effectiveness (ε) vs. number of transfer units (NTU) and capacity ratio (Cr = Cmin/Cmax) for seven flow configurations: parallel-flow, counterflow, shell-and-tube 1-pass, shell-and-tube 2-pass, crossflow both unmixed, crossflow Cmin mixed, crossflow Cmax mixed. Data digitized from Incropera Figures 11.10-11.15.

Mechanical Engineeringhx configuration: Crossflow both unmixed10 rowsPage 2 of 5
hx configurationskcapacity ratio (dimensionless)effectiveness (dimensionless)ntu (dimensionless)
Crossflow both unmixed0.25 0.50.250.370.5
Crossflow both unmixed0.25 1.00.250.581
Crossflow both unmixed0.25 1.50.250.711.5
Crossflow both unmixed0.25 2.00.250.82
Crossflow both unmixed0.25 2.50.250.862.5
Crossflow both unmixed0.25 3.00.250.93
Crossflow both unmixed0.25 4.00.250.954
Crossflow both unmixed0.25 5.00.250.975
Crossflow both unmixed0.50 0.00.500
Crossflow both unmixed0.50 0.50.50.350.5