Effectiveness Ntu: Counterflow

1.00 2.0 to 1.00 5.0

Heat exchanger effectiveness (ε) vs. number of transfer units (NTU) and capacity ratio (Cr = Cmin/Cmax) for seven flow configurations: parallel-flow, counterflow, shell-and-tube 1-pass, shell-and-tube 2-pass, crossflow both unmixed, crossflow Cmin mixed, crossflow Cmax mixed. Data digitized from Incropera Figures 11.10-11.15.

Mechanical Engineeringhx configuration: Counterflow5 rowsPage 5 of 5
hx configurationskcapacity ratio (dimensionless)effectiveness (dimensionless)ntu (dimensionless)
Counterflow1.00 2.010.672
Counterflow1.00 2.510.712.5
Counterflow1.00 3.010.753
Counterflow1.00 4.010.84
Counterflow1.00 5.010.835