Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Design Loads: SPECIAL

impact hangers light to vehicle barrier retail

Structural design loads — live loads, dead loads, special loads per ASCE 7 and IBC codes for various occupancy types

Civil Engineeringload category: SPECIAL7 rowsPage 2 of 2
load categoryload idconcentrated kN (kN)concentrated lbs (lbs)namestandardsubcategoryuniform kPa (kPa)uniform psf (psf)
SPECIALimpact hangers lightImpact factor — light shaft or motor-driven machineryASCE 7-22 §4.7impact
SPECIALimpact machinery reciprocatingImpact factor — reciprocating machineryASCE 7-22 §4.7impact
SPECIALimpact machinery rotatingImpact factor — rotating machineryASCE 7-22 §4.7impact
SPECIALpartition minimumPartition load — minimum for office/hotelASCE 7-22 §4.3.2partition0.71815
SPECIALpartition typicalPartition load — typical heavy partitionsEngineering referencepartition0.95820
SPECIALvehicle barrier garages26.6886,000Vehicle barrier — parking garagesASCE 7-22 §4.5.3vehicle
SPECIALvehicle barrier retail26.6886,000Vehicle barrier — retail/commercialIBC 2024vehicle