Serviceability deflection and drift limits per IBC 2021 Table 1604.3 and ASCE 7-22 — floor beams, roof members, exterior walls, interior partitions, and story drift for seismic and wind

Civil Engineeringmember_type: roof-nonplaster-ceiling3 rows
member typeload caseapplicable load combinationlimit denominator (dimensionless)limit descriptionlimit rationotes
roof-nonplaster-ceilingliveL or Lr240Roof supporting non-plaster ceiling — live loadL/240Span/240 under roof live load
roof-nonplaster-ceilingtotalD + L180Roof supporting non-plaster ceiling — dead plus liveL/180Span/180
roof-nonplaster-ceilingwind-snowS or W240Roof supporting non-plaster ceiling — wind or snowL/240Span/240