Home/Reference Data/Concrete Creep Shrinkage/fib_MC2010#creep_coefficient#80pct#3000psi#I

Concrete Creep Shrinkage: fib_MC2010#creep_coefficient#80pct#3000psi#I

Concrete creep and shrinkage parameters per ACI 209R-92 and fib Model Code 2010 — creep coefficients and shrinkage strains at varying humidity, V/S ratio, loading age, concrete strength, and cement type

Civil Engineeringmodel_param_rh: fib_MC2010#creep_coefficient#80pct#3000psi#I2 rows
model param rhvs loading keycement typeconcrete strength psi (psi)creep coefficient phi (dimensionless)loading age days (day)modelnotesparameter typerelative humidity pct (percent)time after loading days (day)volume to surface ratio in (inch)
fib_MC2010#creep_coefficient#80pct#3000psi#I3in#28d#365tI3,0001.3528fib_MC2010RH=80%: phi_RH correction greatly reduces drying creep; phi_bc(28)~0.6 remainscreep_coefficient803653
fib_MC2010#creep_coefficient#80pct#3000psi#I3in#7d#365tI3,0001.667fib_MC2010Combined: early loading + high humidity; phi_dc nearly eliminated at RH=80%creep_coefficient803653

This is a sample. Search the full concrete creep shrinkage dataset and 300+ more by creating a free account and accessing the database.

Get started for FREE