Compressor Selection Maps: axial

Compressor selection maps per API 617/618/619 — operating envelopes, polytropic efficiency ranges, specific power, surge and turndown limits, molecular weight suitability, discharge temperature limits, capacity control methods, pulsation requirements, lubrication/maintenance intervals, and selection criteria for centrifugal, reciprocating, screw, scroll, diaphragm, and axial compressors

Mechanical Engineeringcompressor_type: axial1 row
compressor typerecord idadiabatic efficiency pct maxadiabatic efficiency pct minadiabatic efficiency pct typical (%)api standarddischarge pressure max psia (psia)discharge pressure min psia (psia)discharge temp max F (degF)flow max acfm (ft^3/min)flow min acfm (ft^3/min)maintenance interval hr (hr)molecular weight max (g/mol)molecular weight min (g/mol)notesparameter categorypolytropic efficiency pct max (%)polytropic efficiency pct min (%)polytropic efficiency pct typical (%)pressure ratio per stage max (dimensionless)pressure ratio per stage min (dimensionless)size classspecific power bhp per 100cfm (hp/(100 ft^3/min))speed rpm max (rpm)speed rpm min (rpm)surge margin pct (%)turndown pct max (%)turndown pct min (%)typical applications
axialoperating_envelope888084API 61715014.7350800,00030,00060,000602Highest flow range; staging 6-20 rows; narrow operating range (surge to stonewall ~20-25%) requires variable stator vanes for control; molecular weight limited to near-air (MW 28-32) typical; efficiency highest of all typesoperating_envelope9285881.31.05all86,0001,500810080Large air separation plants, blast furnace blowers, process air compressors, LNG baseload

This is a sample. Search the full compressor selection maps dataset and 300+ more by creating a free account and accessing the database.

Get started for FREE

Related data