Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Chemical Compatibility: IIR (Butyl)

Dow Corning -220 to Dow Corning -704

Chemical compatibility ratings for elastomers and engineering materials exposed to various chemicals — resistance grades from A (excellent) to D (not recommended), plus X (insufficient data)

Chemical Engineeringmaterial: IIR (Butyl)10 rowsPage 75 of 214
materialchemicalparker compound coderatingrating codetemp max C (degC)temp max F (degF)temp min C (degC)temp min F (degF)
IIR (Butyl)Dow Corning -220N0674-70X-Insufficient DataX120250-59-75
IIR (Butyl)Dow Corning -3E0540-80A-ExcellentA120250-59-75
IIR (Butyl)Dow Corning -33E0540-80A-ExcellentA120250-59-75
IIR (Butyl)Dow Corning -4E0540-80A-ExcellentA120250-59-75
IIR (Butyl)Dow Corning -44E0540-80A-ExcellentA120250-59-75
IIR (Butyl)Dow Corning -5E0540-80A-ExcellentA120250-59-75
IIR (Butyl)Dow Corning -510E0540-80A-ExcellentA120250-59-75
IIR (Butyl)Dow Corning -55E0540-80A-ExcellentA120250-59-75
IIR (Butyl)Dow Corning -550E0540-80A-ExcellentA120250-59-75
IIR (Butyl)Dow Corning -704E0540-80A-ExcellentA120250-59-75