Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Chemical Compatibility: IIR (Butyl)

Cellosolve, Acetate to Cellutherm 2505A

Chemical compatibility ratings for elastomers and engineering materials exposed to various chemicals — resistance grades from A (excellent) to D (not recommended), plus X (insufficient data)

Chemical Engineeringmaterial: IIR (Butyl)10 rowsPage 47 of 214
materialchemicalparker compound coderatingrating codetemp max C (degC)temp max F (degF)temp min C (degC)temp min F (degF)
IIR (Butyl)Cellosolve, AcetateE0540-80B-GoodB120250-59-75
IIR (Butyl)Cellosolve, ButylE0540-80B-GoodB120250-59-75
IIR (Butyl)CelluguardN0674-70A-ExcellentA120250-59-75
IIR (Butyl)Cellulose AcetateE0540-80A-ExcellentA120250-59-75
IIR (Butyl)Cellulose Acetate ButyrateE0540-80A-ExcellentA120250-59-75
IIR (Butyl)Cellulose EtherE0540-80A-ExcellentA120250-59-75
IIR (Butyl)Cellulose Nitrate*E0540-80A-ExcellentA120250-59-75
IIR (Butyl)Cellulose TripropionateE0540-80A-ExcellentA120250-59-75
IIR (Butyl)Cellulube (Phosphate Esters)V3819-75X-Insufficient DataX120250-59-75
IIR (Butyl)Cellutherm 2505AV1164-75D-Not RecommendedD120250-59-75