Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Chemical Compatibility: CSM (Hypalon)

Freon, 11 (Trichlorofluoromethane) to Freon, 12 and Suniso 4G (50/50 Mixture)

Chemical compatibility ratings for elastomers and engineering materials exposed to various chemicals — resistance grades from A (excellent) to D (not recommended), plus X (insufficient data)

Chemical Engineeringmaterial: CSM (Hypalon)10 rowsPage 87 of 214
materialchemicalparker compound coderatingrating code
CSM (Hypalon)Freon, 11 (Trichlorofluoromethane)V3819-75A-ExcellentA
CSM (Hypalon)Freon, 112 (Tetrachlorodifluoroethane)V1164-75B-GoodB
CSM (Hypalon)Freon, 113 (Trichlorotrifluoroethane)C0873-70A-ExcellentA
CSM (Hypalon)Freon, 113 + High and Low Aniline OilN0674-70X-Insufficient DataX
CSM (Hypalon)Freon, 114 (Dichlorotetrafluroethane)C0873-70X-Insufficient DataX
CSM (Hypalon)Freon, 114B2C0873-70A-ExcellentA
CSM (Hypalon)Freon, 115, 116C0873-70X-Insufficient DataX
CSM (Hypalon)Freon, 12 (Dichlorodifluroethane)C0873-70A-ExcellentA
CSM (Hypalon)Freon, 12 and ASTM Oil #2 (50/50 Mixture)V1164-75B-GoodB
CSM (Hypalon)Freon, 12 and Suniso 4G (50/50 Mixture)V1164-75B-GoodB

What else is in Engineering Database

Related data