Chemical Compatibility: CR (Neoprene)

Diphenylamine (DPA) to Dow Corning -200

Chemical compatibility ratings for elastomers and engineering materials exposed to various chemicals — resistance grades from A (excellent) to D (not recommended), plus X (insufficient data)

Chemical Engineeringmaterial: CR (Neoprene)10 rowsPage 74 of 214
materialchemicalparker compound coderatingrating codetemp max C (degC)temp max F (degF)temp min C (degC)temp min F (degF)
CR (Neoprene)Diphenylamine (DPA)V1164-75D-Not RecommendedD107225-51-60
CR (Neoprene)Diphenylene OxideV3819-75X-Insufficient DataX107225-51-60
CR (Neoprene)DiphenylpropaneV1164-75D-Not RecommendedD107225-51-60
CR (Neoprene)DisilaneV3819-75X-Insufficient DataX107225-51-60
CR (Neoprene)Dow Chemical 50-4E0540-80B-GoodB107225-51-60
CR (Neoprene)Dow Chemical ET378FactoryD-Not RecommendedD107225-51-60
CR (Neoprene)Dow Chemical ET588E0540-80B-GoodB107225-51-60
CR (Neoprene)Dow Corning -11E0540-80A-ExcellentA107225-51-60
CR (Neoprene)Dow Corning -1265 Fluorosilicone FluidE0540-80A-ExcellentA107225-51-60
CR (Neoprene)Dow Corning -200E0540-80A-ExcellentA107225-51-60