Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Chemical Compatibility: CR (Neoprene)

Hydrogen Sulfide, Wet, Hot to Hyjet S4

Chemical compatibility ratings for elastomers and engineering materials exposed to various chemicals — resistance grades from A (excellent) to D (not recommended), plus X (insufficient data)

Chemical Engineeringmaterial: CR (Neoprene)10 rowsPage 105 of 214
materialchemicalparker compound coderatingrating codetemp max C (degC)temp max F (degF)temp min C (degC)temp min F (degF)
CR (Neoprene)Hydrogen Sulfide, Wet, HotE0540-80B-GoodB107225-51-60
CR (Neoprene)Hydrolube-Water/Ethylene GlycolN0674-70B-GoodB107225-51-60
CR (Neoprene)HydrooxycitronellalV1164-75D-Not RecommendedD107225-51-60
CR (Neoprene)HydroquinolV1164-75D-Not RecommendedD107225-51-60
CR (Neoprene)HydroquinoneV1164-75D-Not RecommendedD107225-51-60
CR (Neoprene)Hydroxyacetic AcidE0540-80A-ExcellentA107225-51-60
CR (Neoprene)HydyneE0540-80B-GoodB107225-51-60
CR (Neoprene)HyjetE1267-80D-Not RecommendedD107225-51-60
CR (Neoprene)Hyjet IV and IVAE1267-80D-Not RecommendedD107225-51-60
CR (Neoprene)Hyjet S4E1267-80D-Not RecommendedD107225-51-60

What else is in Engineering Database