Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Chemical Compatibility: ACM (Polyacrylate)

Cerium Sulfate to Chloral

Chemical compatibility ratings for elastomers and engineering materials exposed to various chemicals — resistance grades from A (excellent) to D (not recommended), plus X (insufficient data)

Chemical Engineeringmaterial: ACM (Polyacrylate)10 rowsPage 48 of 214
materialchemicalparker compound coderatingrating codetemp max C (degC)temp max F (degF)temp min C (degC)temp min F (degF)
ACM (Polyacrylate)Cerium SulfateE0540-80D-Not RecommendedD177350-21-5
ACM (Polyacrylate)Cerous ChlorideE0540-80D-Not RecommendedD177350-21-5
ACM (Polyacrylate)Cerous FluorideE0540-80D-Not RecommendedD177350-21-5
ACM (Polyacrylate)Cerous NitrateE0540-80D-Not RecommendedD177350-21-5
ACM (Polyacrylate)Cesium FormateE0962-90X-Insufficient DataX177350-21-5
ACM (Polyacrylate)Cetane (Hexadecane)N0674-70A-ExcellentA177350-21-5
ACM (Polyacrylate)Cetyl AlcoholN0674-70A-ExcellentA177350-21-5
ACM (Polyacrylate)Chaulmoogric AcidV3819-75X-Insufficient DataX177350-21-5
ACM (Polyacrylate)China Wood Oil (Tung Oil)N0674-70X-Insufficient DataX177350-21-5
ACM (Polyacrylate)ChloralE0540-80D-Not RecommendedD177350-21-5

What else is in Engineering Database