Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Chemical Compatibility: ACM (Polyacrylate)

Iodine Pentafluoride to Isobutyl Chloride

Chemical compatibility ratings for elastomers and engineering materials exposed to various chemicals — resistance grades from A (excellent) to D (not recommended), plus X (insufficient data)

Chemical Engineeringmaterial: ACM (Polyacrylate)10 rowsPage 107 of 214
materialchemicalparker compound coderatingrating codetemp max C (degC)temp max F (degF)temp min C (degC)temp min F (degF)
ACM (Polyacrylate)Iodine PentafluorideFactoryD-Not RecommendedD177350-21-5
ACM (Polyacrylate)IodoformV1164-75D-Not RecommendedD177350-21-5
ACM (Polyacrylate)Isoamyl AcetateE0540-80D-Not RecommendedD177350-21-5
ACM (Polyacrylate)Isoamyl ButyrateE0540-80D-Not RecommendedD177350-21-5
ACM (Polyacrylate)Isoamyl ValerateE0540-80D-Not RecommendedD177350-21-5
ACM (Polyacrylate)IsoboreolV1164-75D-Not RecommendedD177350-21-5
ACM (Polyacrylate)IsobutaneN0674-70A-ExcellentA177350-21-5
ACM (Polyacrylate)Isobutyl AcetateE0540-80D-Not RecommendedD177350-21-5
ACM (Polyacrylate)Isobutyl AlcoholE0540-80D-Not RecommendedD177350-21-5
ACM (Polyacrylate)Isobutyl ChlorideV1164-75X-Insufficient DataX177350-21-5