methodphi degN gamma (dimensionless)Nc (dimensionless)Nq (dimensionless)Nq Nc ratio (dimensionless)
Hansen202.94782814.8347126.3993940.43138
Hansen213.49552215.8148837.0707650.447096
Hansen224.13386716.8828657.821120.463258
Hansen234.87797418.0486348.661190.479881
Hansen245.74571719.323549.6033940.496979
Hansen256.75829620.72053110.6621420.514569
Hansen267.94092322.25441411.8542030.532667
Hansen279.32366323.94217313.1991460.551293
Hansen2810.94248525.80334314.7198810.570464
Hansen2912.84054827.86046516.4433080.590202