Anchor Bolt Design: PIW-1.5-A36-carbon-6.5
Anchor bolt design parameters per ACI 318-19 Chapter 17 — cast-in-place headed bolts and post-installed anchors (wedge and adhesive). Steel failure mode nominal tensile (Nsa) and shear (Vsa) strengths. Concrete breakout must be checked separately.
| anchor id | Fu ksi (ksi) | Nsa kips (kips) | Vsa kips (kips) | anchor area in2 (in2) | anchor type | concrete fc psi (psi) | embedment depth in (in) | min embedment std in | min spacing in (in) | nominal diameter in (in) | standard | steel grade |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PIW-1.5-A36-carbon-6.5 | 58 | 92.8 | 55.7 | 1.767 | post-installed-wedge | 3,000 | 6.5 | 6.5 | 7.5 | 1.5 | ACI 318-19 Ch.17 | A36-carbon |
What else is in Engineering Database
Iron Engine ↗Engineering AI at ironengine.ai
AI built for engineering. Searches the engineering database, performs calculations, gives source-backed engineering insights.
Get started for free ↗Reference Data375 engineering tablesMaterial properties, pipe and shape dimensions, code tables, and electrical ratings across mechanical, civil, chemical, electrical, materials, and manufacturing engineering.
Browse dataCalculatorsDeterministic engineering calculatorsSizing, checking, and conversion tools that run against the reference tables. Inputs are code-compliant, outputs are traceable to the source standard.
Browse calculatorsCalculators that use this data
Related data
CIP-0.5-F1554-36-3.51 rowCIP-0.625-F1554-36-4.3751 rowCIP-0.75-F1554-36-4.51 rowCIP-0.875-F1554-36-5.251 rowCIP-1.0-F1554-36-6.01 rowCIP-1.125-F1554-36-6.751 rowCIP-1.25-F1554-36-7.51 rowCIP-1.5-F1554-36-9.01 rowCIP-0.75-F1554-55-6.01 rowCIP-1.0-F1554-55-8.01 rowCIP-1.25-F1554-55-10.01 rowCIP-1.5-F1554-55-12.01 row