Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Anchor Bolt Design: PIA-1.0-A193-B7-7.5

Anchor bolt design parameters per ACI 318-19 Chapter 17 — cast-in-place headed bolts and post-installed anchors (wedge and adhesive). Steel failure mode nominal tensile (Nsa) and shear (Vsa) strengths. Concrete breakout must be checked separately.

Civil Engineeringanchor id: PIA-1.0-A193-B7-7.51 row
anchor idFu ksi (ksi)Nsa kips (kips)Vsa kips (kips)anchor area in2 (in2)anchor typeconcrete fc psi (psi)embedment depth in (in)min embedment std inmin spacing in (in)nominal diameter in (in)standardsteel grade
PIA-1.0-A193-B7-7.5125100600.785post-installed-adhesive3,0007.57.561ACI 318-19 Ch.17A193-B7

What else is in Engineering Database

Calculators that use this data

Related data