Steel 50G GOST 1050-88 vs Steel 50L GOST 977-88
Property comparison of Steel 50G GOST 1050-88 and Steel 50L GOST 977-88, both carbon steel.
| Property | Steel 50G GOST 1050-88 | Steel 50L GOST 977-88 | Difference |
|---|---|---|---|
| Yield strength | 400 MPa | 392 MPa | -2% |
| Tensile strength | 660 MPa | 736 MPa | +12% |
| Elastic modulus | 216,000 MPa | 205,000 MPa | -5% |
| Shear modulus | 84,000 MPa | 79,000 MPa | -6% |
| Poisson ratio | 0.29 | 0.3 | +3% |
| Density | 7,810 kg/m³ | 7,820 kg/m³ | 0% |
| Thermal conductivity | 54 W/m·K | 54 W/m·K | 0% |
| Specific heat | 465 J/kg·K | 465 J/kg·K | 0% |
| Coefficient of thermal expansion | 0.000012 1/K | 0.000012 1/K | 0% |
| Melting point | 1,480 °C | 1,480 °C | 0% |
Difference is Steel 50L GOST 977-88 relative to Steel 50G GOST 1050-88. Values are taken from the representative row of each material; both materials may have multiple heat treatments or conditions on their individual pages.
Identification
- standard
- GOST
- heat treatment
- normalized
- standard
- GOST
- heat treatment
- Quenched and tempered