Nimonic 105 (Ni-15Cr-20Co-5Mo-4.7Ti-1.2Al) precipitation hardened vs Nimonic 263 / Alloy C-263 (Ni-20Cr-20Co-6Mo-2Ti-0.6Al) precipitation hardened
Property comparison of Nimonic 105 (Ni-15Cr-20Co-5Mo-4.7Ti-1.2Al) precipitation hardened and Nimonic 263 / Alloy C-263 (Ni-20Cr-20Co-6Mo-2Ti-0.6Al) precipitation hardened, both nickel alloy.
| Property | Nimonic 105 (Ni-15Cr-20Co-5Mo-4.7Ti-1.2Al) precipitation hardened | Nimonic 263 / Alloy C-263 (Ni-20Cr-20Co-6Mo-2Ti-0.6Al) precipitation hardened | Difference |
|---|---|---|---|
| Yield strength | 770 MPa | 550 MPa | -29% |
| Tensile strength | 1,150 MPa | 940 MPa | -18% |
| Elongation | 25 % | 39 % | +56% |
| Density | 8,010 kg/m³ | 8,360 kg/m³ | +4% |
| Thermal conductivity | 10.9 W/m·K | 11.7 W/m·K | +7% |
| Coefficient of thermal expansion | 0.000012 1/K | 0.00001 1/K | -16% |
| Melting point | 1,317 °C | 1,327 °C | +1% |
Difference is Nimonic 263 / Alloy C-263 (Ni-20Cr-20Co-6Mo-2Ti-0.6Al) precipitation hardened relative to Nimonic 105 (Ni-15Cr-20Co-5Mo-4.7Ti-1.2Al) precipitation hardened. Values are taken from the representative row of each material; both materials may have multiple heat treatments or conditions on their individual pages.
Identification
- grade
- N/A
- standard
- Special Metals Corp. tech bulletin NIMONIC alloy 105 (SMC-093)
- heat treatment
- solution treat 1149C/4h AC + age 1056C/4h AC + 849C/16h AC
- grade
- N07263
- standard
- Special Metals Corp. tech bulletin NIMONIC alloy C-263 (SMC-094)
- heat treatment
- solution treat 1150C AC + age 800C/8h AC