Concrete6 compared properties
PropertyNormal Weight Concrete fc=50 MPaUltra-High Performance Concrete (UHPC)Difference
Elastic modulus33,440 MPa48,000 MPa+44%
Poisson ratio0.180.2+11%
Density2,450 kg/m³2,550 kg/m³+4%
Thermal conductivity2 W/m·K2 W/m·K0%
Specific heat880 J/kg·K880 J/kg·K0%
Coefficient of thermal expansion0.00001 1/K0.000014 1/K+35%

Difference is Ultra-High Performance Concrete (UHPC) relative to Normal Weight Concrete fc=50 MPa. Values are taken from the representative row of each material; both materials may have multiple heat treatments or conditions on their individual pages.

Identification

Normal Weight Concrete fc=50 MPa
standard
ACI
Ultra-High Performance Concrete (UHPC)
standard
FHWA